  • A simplified single edition offering

  • Reduced data transfer during resynchronization with Geographic Mirroring Compression

  • Reduction in Time Required to Perform CRG Switchover for Selected Configurations

Note

Required PTF: PTF SI78996 (plus language PTFs) is a required PTF for PowerHA on IBM i 7.5.

...

With this enhancement, PowerHA can now compress geographic mirroring data during resynchronization reducing the data transfer required. In addition, on Power10 systems, PowerHA uses the on-chip NX GZIP accelerator if the NX feature is enabled, providing hardware accelerated compression. This enhancement will be available on June 24th, 2022 for both PowerHA 7.5 and 7.4.

Reduction in Time Required to Perform CRG Switchover for Selected Configurations
Status
colourYellow
title7.5 HA 5.0.1
Status
colourGreen
title7.4 HA 4.6.1
Status
colourPurple
title7.2 HA 3.8 (IBM i 7.3)

Previously, when performing a switchover of a device Cluster Resource Group (CRG), the job queue specified in the job description for the user performing the switchover was used to vary off and on the IASP. This may result in the switchover taking longer than expected. For example, if the job queue is held or only allows a specific number of active job at a time, the switchover may be held up for a long time. Previously, PowerHA included switchover progress monitoring that visually indicates a job submitted but not yet running to help identify these situations.

PowerHA has been enhanced so that planned switchovers or unplanned failovers will always use the QSYSNOMAX job queue for IASP vary on and off operations regardless of the user initiating the operation. This reduces the chance of a held job queue or hitting the restriction on the maximum number of active jobs in the subsystem, reducing the time required to perform the CRG switchover.

Note: This does not affect CRG user exit programs; the job queue referenced by the user profile parameter specified when creating or changing the CRG will continue to be used. The job queue specified in the user profile’s job description is used for submitting user exit programs regardless of the user initiating the planned switchover operation.

...