Automatic duplication:
From devices . . . . . . . . . Name Name, *NONE, *SAME, *MEDCLS.
From device end option . . . . *REWIND *REWIND, *LEAVE, *UNLOAD
To devices . . . . . . . . . . *SAME Name, *SAME, *MEDCLS, F4
To device end option . . . . . *REWIND *REWIND, *LEAVE, *UNLOAD
To media policy . . . . . . . *SAME *SAME, *SYSPCY, F4
Save media information . . . . *SAME *SAME, *BKUPCY, *LIB, *OBJ
*NONE
...
BRMS submitted jobs:
Job description. . . . . . . . . . . . *USRPRF Name, *USRPRF
Library. . . . . . . . . . . . . . . *LIBL Name, *LIBL, *CURLIB
Job queue. . . . . . . . . . . . . . . *JOBD Name, *JOBD
Library. . . . . . . . . . . . . . . *LIBL Name, *LIBL, *CURLIB
NOTES:
Automatic duplication is only supported for backups run with the Start Backup using BRM (
is notSTRBKUBRM
) command, itis not supported for backups run with the
SAVxxxBRM
commands or the Start Archive using BRM (STRARCBRM
) command.If a control group is set up to do an IPL after it completes, the automatic duplication job(s) will not be submitted.
orDUPMEDBRM VOL(*SEARCH)
or
DUPMEDBRM VOL(*SCHHST)
will need to be run to duplicate any media or saved items marked for duplication after the system has been IPL'd.When using automatic duplication,it is recommended that duplication' and 'Mark history for duplication' be set to *NO in the media policy. If one or both of these are set to *YES, the 'Mark volume for duplication' is cleared once the auto duplication has completed. If 'Mark history for duplication' is set to '*YES', then it is expected that you intend to perform a second duplication in addition to the auto duplication, and a
DUPMEDBRM *SCHHST
will need to be run.When using automatic duplication, a batch job for each media set from the save is submitted and runs
DUPMEDBRM VOL(*LIST)
using theFROMSEQNBR('startingseq#' 'endingseq#')
from the control group save. It is not necessary to mark media or history for duplication in the media policy.When doing parallel saves that use multiple logical or physical tape media libraries, the automatic duplication function may not work unless each logical library has multiple compatible drives available.
Automatic duplication does not allow a sequence number to be specified for the To device. By default, the sequence number for the To device is 1 which will cause a new volume to be used for each volume set being duplicated. It may be desirable for each of the volume sets being copied to be appended to the output volume on the To device. If wanting to duplicate many to one, the subsystem where the submitted jobs are sent to should have a maximum active set to 1. The following command can be used to force the copied input volumes to be appended to the volume on the To device:
CHGCMDDFT CMD(DUPMEDBRM) NEWDFT('TOSEQNBR(*END)')