  • Formatting was changed.

...

  • Customer instances have been reported when using DSLO media to upgrade systems from installing 7.3 to 7.4.  Installing 5770SS1 Option 3 may report a failure because a *SYMLINK in 7.3 was changed to a *STMF hard link in 7.4.  Restoring the 7.4 file over the pre-existing *SYMLINK cannot be done.  To avoid this problem when creating DSLO media for installing 7.4 installation, prior to the upgrade install the 7.3 *SYMLINK needs to be removed by running the following command:

...

NOTE: The exact QPZxxxxxx or QPZRxxxxxx logical file name should be used, do not use the generic value QPZA* or QPZR* in the DLTF command.

This problem could happen with any incorrect logical files on BRMS files in library QBRM. To address similar file problems on an upgrade, if logical files are reported missing after the 7.4 upgrade BRMS recommends the following options:

...

NOTE: The exact logical file name should be used, do not use a generic value in the DLTF command.

Option 2 - DSLO (Coming in September 2020 PTFs)

...