Change Control Group (Q1ACHGCGA) API

Change Control Group (Q1ACHGCGA) API

The (Q1ACHGCGA), Change Control Group Attributes  API



  Required Parameter Group:
 

1

Control group name

Input

Char(10)

2

Attribute information

Input

Char(*)

3

Length of attribute information

Input

Binary(4)

4

Format of attribute information

Input

Char(8)

5

Error Code

I/O

Char(*)


Program: QBRM/Q1ACHGCGA
  Default Public Authority: *USE

  Threadsafe: No 
 

The Change Control Group Attributes (Q1ACHGCGA) API is used to enable users to change programmatically the control group attributes.

 

Authorities and Locks

None

 

Required Parameter Group

Control group name: INPUT, CHAR(10); Specifies the name of the control group that is being created.

Attribute information: INPUT, CHAR(*); The attributes of the control group. The format of the control group information is specified in the control group format name parameter.

Length of attribute information: INPUT, BINARY(4); The number of bytes that the calling program provides for the attribute information format.

Format of attribute information: INPUT, CHAR(8); The format of the attribute information parameter. The possible format names include:

CGBI0100, See Attribute information formats below for a description of this format.  

Error code: I/O, CHAR(*); The structure in which to return error information. For the format of the structure, see the Error code parameter section below.

 

CGBI0100 Attribute information formats

Offset

Type

Field

Dec

Hex

0

0

CHAR(40)

Backup control group devices

40

32

CHAR(10)

Backup control group full media policy

50

3C

CHAR(10)

Backup control group incremental media policy

60

40

CHAR(4)

Reserved


 

Attribute information format field descriptions:

Backup control group devices. Specifies an array of device names associated with this object. The array is limited to a maximum of four device names. The default value is *BKUPCY, if all the device names are blanks.

Offset

Type

Field

Dec

Hex

0

0

CHAR(10)

Device n

Note: These fields repeat for each device name The device names must be 10 characters. The number of device names in the array is 4 for a total of 40 characters. For unused device names, the 10-byte field must be set to blanks.

 

 

*NONE

Specifies no devices will be used. The media policy is set to use save files instead of devices. This special value must be first in the array. The other 3 device name fields must be blank.

*MEDCLS

Specifies the device(s) are determined from the media class attribute of the media policies assigned to this control group. 
Restrictions: Can only have multiple *MEDCLS if no parallel or virtual device is being used on the backup. Multiple *MEDCLS will be used as a way to cascade the serial backup to other devices.

*BKUPCY

The value of the BRMS backup policy will be used on the backup. The other 3 device name fields must be blank.

*SYSPCY

The value of the BRMS system policy will be used on the backup. The other 3 device name fields must be blank.

device-name-n

The name of the device object. 
Restrictions: Can only have 1 device if a virtual device is being used and not using parallel backups.

Backup control group full media policy. Specifies the name of the media policy for full backups.

*BKUPCY

The value of the BRMS backup policy will be used on the backup.

*SYSPCY

The value of the BRMS system policy will be used on the backup.

Media policy name

The name of the media policy to use on the backup.

 

Backup control group incremental media policy. Specifies the name of the media policy for incremental backups.

*BKUPCY

The value of the BRMS backup policy will be used on the backup.

*SYSPCY

The value of the BRMS system policy will be used on the backup.

Media policy name

The name of the media policy to use on the backup.

 

Error Messages

The following messages may be sent from this function:

Message ID

Error Message Text

CPF3CF1 E

Error code parameter not valid.

CPF24B4 E

Server error while addressing parameter list.

CPF5222 E

Name is not valid.

CPF9800 E

All CPF98xx messages could be signaled (xx range is 01 to FF).

BRM1199 E

Special values and device names cannot be mixed.

BRM1243 E

Duplicate devices not allowed.

BRM1437 E

Save to savefile must be *YES in policy * if device is *NONE.

BRM1430 E

Device * not found.

BRM1881 E

Device * not compatible with media policy *.

BRM3011 E

Multiple *MEDCLS not allowed.

BRM3C1E E

Required parameter omitted.

BRM3C4B E

Value not valid for field at offset *.

BRM3C4C E

Value not valid for field at offset *

BRM3C91 E

Product feature required.

BRM3C99 E

Unexpected condition with * API. Reason *.

BRM402A E

BRMS product initialization required.

BRM4040 E

Access denied for user *.

BRM4104 E

Control group * not found.

BRM4108 E

Format name * not correct.

Privacy Policy | Cookie Policy | Impressum
From time to time, this website may contain technical inaccuracies and we do not warrant the accuracy of any posted information.